Fix setting gamma-tables that are not symmetrical (items / range)
Libksane expected gamma-tables to have as many entries as the maximum value in the table. This is not the case for example in the niash backend. This patch will hopefully fix the setting of gamma-table for the niash backend. I do not have a scanner that has an asymmetrical gamma-table, so I cannot test this fully. BUG: 370972 FIXED-IN: KDE Applications 18.12 Also change names of some variables to follow KF5 coding standards
parent
e387aa42
Please register or sign in to comment